PRODUCT SEARCH
CONTACT

Add: Room 2001、2002、2003、2011, Zhonghai International Plaza No. 237, Wannianquan Road, Qingdao, Shandong 266199 China

Tel: +86 532 8281 2277

Mobile : +86 186 5320 8877(WhatsApp)

Email: market@hiprove.cn   lena@hiprove.cn

PRODUTS

Current location:Home >Products>Anesthesia machine

MJ-560B2 Anesthesia Machine

Part parameters

Packaging Details:
Delivery Time:
Description: MJ-560B2 Anesthesia Machine, designed with state-of-the-art technologies, is one of high utility with excellent performance and complete functions. Both outstanding and inexpensive, it has the best cost performance that can satisfy any customer.

Detailed introduction:

1.The Ventilator adopts microcomputer control with high-definition 5.7" LCD display, integrating the functions of respiratory control and displaying the monitoring parameters. It is versatile in function and excellent in performance.
2.The high-precision Vaporizer is designed with a stable concentration output, automatic compensation for pressure, temperature and flow rate. And it is available to choose one kind of gas from Halothane, Enflurane,Isoflurane,
3. Sevoflurane, ensuring a successful anesthesia operation
4. Reliable pneumatic transmission system.
5. Economic and proper configuration of technologies, optional as required by the customer.

6. Modulatized design and upgrading. Upgrading is available as required by the customer.

 

 

  Anesthesia Machine  
* Main body High-strength engineering plastic rack, light, beautiful and corrosion resistant
* Scope of application aduit, child
* Gas source O2: 0.27~0.55MPa   N2O : 0.27~0.55MPa
* Flow meter O2:0.1~10L/min   N2O : 0.1~10L/min
* O2, N2O linkage and N2O Stopper
  When using nitrous oxide, oxygen concentration>25%; When the oxygen pressure<0.2MPa, the flow of nitrous oxide would be cut off.
* Flow rate of rapid oxygen supply 25~75L/min
* Low oxygen pressure alam There will be sound alarm when the oxygen pressure <0.2MPa
* Vaporizer
  it has the function of automatic compensation based on pressure, temperature and flow rate, The regulation range of evaporator concentration is 0-5 vol%. Among Halothane, Enflurane, lsoflurane and Sevoflurane, one can be chosen for application as required by the customer.And vaporizers that are imported with original packaging are also available.
* Respiratory circuit Work mode: all-close, semi-close, semi-open release pressure: 1~ 4KPa
* Respiratory Bellows bellows for adults, bellows for children tidal volume range: 0~1500ml
 

 

 

  Ventilator  
* Display mode High-definition 5.7 " LCD screen display
* Ventilation mode  
  IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH
* Ventilation parameters  
  Tidal volume 50~1500ml
  Rate 2~99bpm
  SIMV rate 2~20bpm
  I : E 2:1~1:8
Inspiratory trigger pressure -1.0~2.0KPa
PEEP 0~2.0KPa
  Pressure range 1.0~6.0kpa
SIGH 1.5 times the inspiratory time
* Parameters for ventilation monitoring
  tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory
rate,I/E, peak pressure of airway, pressure - time waveform ,PEEP, inspiratory trigger pressure
* Monitoring of oxygen concentration 21%~100%
* Security Alert System  
  Oxygen Concentration alarm upper limit setting range 50%-100%
low limit setting range 15%-50%
Airway pressure alarm upper limit setting range 1.0-6.0kpa
low limit setting range 0.4-2.0kpa
  Per - minute ventilation volume alarm upper limit setting range 3.0-30L/min
low limit setting range 1.0-10L/min
  Sustained high - pressure alarm it will give alarm when stress have
consistently been higher than 2.5 kpa
  Suffocation alarmPower alarm it will give sound and light alarm if there is
no tidal volume input for 15 seconds
* Power AC 220v±10% 50Hz ±1HZ
( UPS, Storage battery )