AV-200B3 Ventilator

Part parameters
- Packaging Details:
- Delivery Time:
- Description: The AV-2000B3 is a multi-functional Ventilator adopting pneumatic, electronic control and microcomputer technology.Exported components are utilized to guarantee operational stability and reliability. With color screen ( TEF) to display various measuring and configuration parameters, the device is very suitable for respiratory treatment, applicable for medical, surgical and gyneeological departments, the department of pediatries, first aid, and ICU departments of hospitals at diffdrent levels.
Detailed introduction:
| Ventilator | ||
| * | Display mode | High-definition 10.4 " TFT color LCD screen display |
| * | Ventilation mode | |
| IPPV,SIPPV, SIMV,PEEP,MANUAL,SIGH ( IMV VCV PCV) | ||
| * | Ventilation parameters | |
| Tidal volume | 50~1500ml (20~1500ml ) | |
| Rate | 1~99bpm | |
| SIMV rate | 2~20bpm | |
| I : E | 2:1~1:8 (4:1~1:8 ) | |
| Inspiratory trigger pressure | -1.0~2.0kpa | |
| PEEP | 0~2.0kpa | |
| Pressure range | 1.0~6.0kpa | |
| SIGH | 1.5 times the inspiratory time | |
| 70-150 adjustable | ||
| Inspiratory platform | 0-50% | |
| * | Parameters for ventilation monitoring | |
| tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate,I/E, peak pressure of airway,average pressure, pressure - time waveform, flow rate - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure, Inspiratory platform ( autonomous inspiratory rate, lung compliance, airway resistance, flow - volume loop, pressure-volume loop) |
||
| * | Security Alarm System | |
| Airway pressure alarm | upper limit setting range 21%-100% | |
| low limit setting range 10%-80% | ||
| upper limit setting range 0.3-6.0kpa | ||
| low limit setting range 0.2-5.0kpa | ||
| Per - minute ventilation volume alarm | upper limit setting range 3.0-30L/min | |
| low limit setting range 1.0-10L/min | ||
| Sustained high - pressure alarm | it will give alarm when stress have | |
| consistently been higher than 2.5 kpa | ||
| Suffocation alarmPower alarm | it will give sound and light alarm if there is | |
| no tidal volume input for 15 seconds | ||
| * | Power | AC 220v±10% 50Hz ±1HZ |
| UPS ,Storage battery | ||
| * | Mechanical Arms | |
| * | M( Air compressor) Items within brackets are optional. | |